MRV Communications AE092FCAKA Specifiche

Navigare online o scaricare Specifiche per Climatizzatori a split MRV Communications AE092FCAKA. MRV Communications AE092FCAKA Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 69
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Getting Started with the LX Series
451-0308E
Corporate Headquarters
MRV Communications, Inc. Corporate Center
20415 Nordhoff Street
Chatsworth, CA 91311
Tel: 818-773-0900
Fax: 818-773-0906
www.mrv.com
(Internet)
Sales and Customer Support
MRV Americas
295 Foster Street
Littleton, MA 01460
Tel: 800-338-5316 (U.S.)
Tel: +011 978-952-4888 (Outside
U.S.)
sales@mrv.com (email)
www.mrv.com
(Internet)
MRV International
Industrial Zone
P.O. Box 614
Yokneam, Israel 20682
Tel: 972-4-993-6200
sales@mrv.com (email)
www.mrv.com
(Internet)
Vedere la pagina 0
1 2 3 4 5 6 ... 68 69

Sommario

Pagina 1

Getting Started with the LX Series451-0308ECorporate HeadquartersMRV Communications, Inc. Corporate Center20415 Nordhoff StreetChatsworth, CA 91311Tel

Pagina 2

10451-0308

Pagina 3

451-030811PrefaceThis guide describes how to install the software, describes the hardwareand cabling, as well as how to rack-mount the LX Series. This

Pagina 4

Preface12451-0308• Getting Started with MRV Communications LX Series MIBs - Providesbasic information regarding the Network Management System (NMS),an

Pagina 5 - Table of Contents

451-030813Chapter 1Overview of the LX SeriesThe LX Series is a secure standalone communication server that isdesigned for applications requiring secur

Pagina 6

Overview of the LX Series14451-0308• Configure Mode prompt – A sample configure mode prompt isAsync 1-6:0 >>, where Async is a reminder that te

Pagina 7

451-030815Overview of the LX Series• Ctrl-B – Moves back to the previous session.• Ctrl-L – Returns you to the Local Command Mode.NOTE: You must press

Pagina 8

Overview of the LX Series16451-0308

Pagina 9

451-030817Chapter 2Installing the LX SeriesHardware InstallationThis section explains how to install an LX Series Communications serverand place it in

Pagina 10 - 451-0308

Installing the LX Series18451-0308LX Indicators and Interfaces This section explains the LX unit’s indicators and interfaces. Front Panel LEDsThis sec

Pagina 11 - Other Documentation

451-030819Installing the LX SeriesFLTSolid red indicates a fault condition exists or maintenance is required. ThisLED remains on until the initial Pow

Pagina 12

2451-0308All rights reserved. No part of this publication may be reproduced without the prior written consent of MRV Communications, Inc. The informat

Pagina 13 - Overview of the LX Series

Installing the LX Series20451-0308Figure 6 - LX Series 4008M with Modem Rear PanelFigure 7 - LX Series 4016M with Modem Rear Panel100-2 40VAC1.0A 50/6

Pagina 14

451-030821Installing the LX SeriesFigure 8 - LX Series 4016 DC Version Rear PanelFigure 9 - LX Series 4032M with Modem Rear Panel91011 121314 1516

Pagina 15 - System Specifications

Installing the LX Series22451-0308Figure 10 - LX Series 4032M DC Version Rear PanelFigure 11 - LX Series 4048 AC Rear PanelRCVThe RCV LED is one of tw

Pagina 16

451-030823Installing the LX SeriesEnvironmental and Installation Considerations• Unit must be installed in an environment with 20% to 80% humidity,non

Pagina 17 - Installing the LX Series

Installing the LX Series24451-0308Mounting the Unit into a 19-inch or 23-inch RackAttach the brackets to the unit, and then mount the unit in the rack

Pagina 18 - LX Indicators and Interfaces

451-030825Installing the LX SeriesCable ConnectionsThis section explains the cable connections for the LX unit.Connect the Power CableConnect the supp

Pagina 19 - DIAG Port (Port 0)

Installing the LX Series26451-0308Connecting DC PowerThis section describes how to connect power to the DC version of the LXSeries 4008, 4016, and 403

Pagina 20

451-030827Installing the LX SeriesNOTE: The LX will run with only one DC power feed connected. Thesecond input is provided for redundant system power,

Pagina 21

Installing the LX Series28451-0308When the POST test is completed, the Main menu appears. The system loadsthe IROS operating system from flash and the

Pagina 22

451-030829Installing the LX SeriesThese passwords prevent persons who do not know them from accessing theserver. Change the default passwords to other

Pagina 23

451-03083CAUTIONThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

Pagina 24

Installing the LX Series30451-0308If the LX Series does not detect an error, the unit begins loading softwarefrom the internal flash. Once loaded, the

Pagina 25 - Cable Connections

451-030831Installing the LX SeriesUse the following procedure to configure your LX unit for the first time.1. Plug in the terminal at the DIAG port (p

Pagina 26 - Connecting DC Power

Installing the LX Series32451-0308NOTE: You should change the Superuser Password, since this is the firsttime you are configuring the LX unit (the def

Pagina 27 - Powering On

451-030833Installing the LX Series• To use the CLI, refer to Figure 16 for the CLI tree structure and to theLX-Series Commands Reference Guide for inf

Pagina 28 - System Login and Passwords

Installing the LX Series34451-03081. At your browser, type the IP address or hostname of your LX unit. TheLX Series Configuration Console page appears

Pagina 29 - IMPORTANT

451-030835Installing the LX Series2. When you select Encrypted Console or Not Encrypted Console at theLX Series Configuration Console page, and the sy

Pagina 30

Installing the LX Series36451-0308NOTE: The java cache in JRE 1.4 is set ON by default. There is a knownproblem within JRE 1.4 regarding cache functio

Pagina 31

451-030837Installing the LX Series6. Enter your Username and Password, and click Login.NOTE: By default, authentication is done against the LX local u

Pagina 32

Installing the LX Series38451-0308Software UpgradesTo upgrade software using the ppciboot menu, refer to “UpgradingSoftware with the ppciboot Main Men

Pagina 33

451-030839Installing the LX SeriesAccessing and Configuring Additional FeaturesThe following sections describe additional LX features you can access a

Pagina 34

4451-0308

Pagina 35

Installing the LX Series40451-0308Accessing from a Terminal Attached to an LX Series Serial PortUse the following procedure to access the command line

Pagina 36

451-030841Installing the LX SeriesTo connect the sensor: 1. Connect one end of the RJ-45 double-ended straight through cable tothe temperature/humidit

Pagina 37

Installing the LX Series42451-03083. You can also monitor the temperature/humidity remotely through the LX CLI. Refer to the LX-Series Commands Refere

Pagina 38 - Booting from Defaults

451-030843Installing the LX Seriesppciboot Factory Default SettingsThe following table lists the factory default settings.NOTE: For defaults on specif

Pagina 39

Installing the LX Series44451-0308Additional Considerations for an Internet EnvironmentIf you plan to use the unit in an Internet environment, you mus

Pagina 40 - Additional Considerations

451-030845Appendix ATechnical SpecificationsThe following table provides the specifications for the LX Series. Table 1 - LX Series SpecificationsItem

Pagina 41

Technical Specifications46451-0308DimensionsHeight Depth WidthLX Series4.1 cm (1.62 in), LX-4048 - 4.34 cm (1.71 in)21.5 cm (8.5 in)48.2 cm (19 in)Wei

Pagina 42

451-030847Technical SpecificationsPower Requirements LX-4008 AC - 11W, (38BTU/hr) 0.09A at 120V (typ), 11W 0.05A at 220V (typ)LX-4008 DC - -48VDC Nomi

Pagina 43

Technical Specifications48451-0308

Pagina 44 - Autobauding Feature

451-030849Appendix BPOST Test Error CodesError Code DefinitionsThe following table provides the definitions for the LX Series POST testerror codes. Ta

Pagina 45 - Technical Specifications

451-03085Table of ContentsPreface... 11C

Pagina 46

POST Test Error Codes50451-0308CPLD FAIL bit is set in the CPLD System Fail Status Register2035DC_A bit is set in the CPLD System Fail Status Register

Pagina 47

451-030851POST Test Error CodesPOST Test Error Code SampleNOTE: This example applies to 8, 16, 32, and 48 port LX units. The 16, 32, and 48 port LX un

Pagina 48

POST Test Error Codes52451-03081. A POST test failure occurs on an 8-port unit. All LEDs flash eighttimes, very quickly, then the error code is displa

Pagina 49 - POST Test Error Codes

451-030853POST Test Error CodesFigure 17 - POST Test Error Code Sample1 - All flash for 2 seconds2 - High error code (20 Hex)3 - Cycle 1 through 84 -

Pagina 50

POST Test Error Codes54451-0308

Pagina 51 - POST Test Error Code Sample

451-030855Appendix CCabling the LX SeriesCabling ConsiderationsStandard cabling items available from MRV Communications allow you toconnect to any ser

Pagina 52

Cabling the LX Series56451-030810/100 ConnectorFigure 19 shows the standard 10/100 (RJ-45 jack) connector signalassignments.Figure 19 - 10/100 Connect

Pagina 53 - 1 2 3 4 5 6 7 8

451-030857Cabling the LX SeriesPin AssignmentsThe following table shows the pinouts for the DB-25 cable.Pin Signal1 Cable Shield2Transmit Data3 Receiv

Pagina 54

Cabling the LX Series58451-0308Figure 20 shows serial DB-25 pin assignments. Figure 20 - DB-25 Pins22 Ring Indicate23 Unused24 Unused25 Unused14DB-2

Pagina 55 - Cabling the LX Series

451-030859Cabling the LX SeriesOrdering and Installing the Inlet Connector LockYou can use an inlet connector lock to lock the AC power cord to the LX

Pagina 56 - Modular Adapters

6451-0308Sensor (Temperature/Humidity) Ports ...40Connecting the Temperature/Humid

Pagina 57 - Pin Assignments

Cabling the LX Series60451-0308Modem Control/Hardware Flow ControlLX Series serial ports can be set up to support RTS/CTS flow control. Theadapters sh

Pagina 58 - (Female)

451-030861Cabling the LX SeriesModular Adapters (RJ-45 to DB-25)You can obtain adapters with male and female DB-25 connectors fromMRV Communications.

Pagina 59

Cabling the LX Series62451-0308Figure 23 - Adapter Wiring, RJ-45 to DB-9, LX Series to DTECTSDTRXMTGNDRCVDCDDSRRTSFemale RJ-45ConnectorFemale DB-25Con

Pagina 60 - RJ-45 Wiring Considerations

451-030863Cabling the LX SeriesFigure 24 - Adapter Wiring, LX Series to DCELX SeriesConnectorFemaleRJ-45MaleRJ-45MaleRJ-45Straight Through Ca

Pagina 61 - LX Series

Cabling the LX Series64451-0308NOTE: In order to expand the functionality of the serial interface, the LXSeries modular cabling allows you to connect

Pagina 62

451-030865Cabling the LX SeriesFigure 25 - Modular Cables for RTS/CTS Flow Control (Eight-Wire), Concur-rent with Modem Control SignallingCommunicati

Pagina 63 - Supports RTS/CTS

Cabling the LX Series66451-0308

Pagina 64

451-030867INDEXNumerics10/100 connectors 568-wire cabling 64Aadapter wiring 61adapters 61autobauding feature 44Ccablesordering 56cabling 25, 45signals

Pagina 65 - Connector

INDEX68451-0308link 22OK 19receive 22speed 22LEDs 19, 29, 45port status 19LINK LED 22login username 28default 28LX Indicators 18LX series4008 rear pan

Pagina 66

451-030869INDEXSsensor ports 40serial device cablesconnecting to RJ-45 jacks 25serial portsnumber of 45signals 45speed LED 22speeds 45system login 28s

Pagina 67

451-03087FiguresLX Series 4008 Front Panel... 18LX Series 4016 Front Panel

Pagina 68

8451-0308

Pagina 69

451-03089TablesLX Series Specifications .....................45POST Test Error Codes .

Commenti su questo manuale